Skip to main content

Outlast power outages

How the Lunar System provides backup during grid outages

Written by Shakeel Ahmed

Power outages can happen unexpectedly and last for hours, or even days. With 20 kWh of battery capacity, the Lunar System brings you energy independence and security, so life in your home can carry on uninterrupted during a power outage.

How the Lunar System provides backup power for your home

When the grid fails, your Lunar System disconnects from the grid and restores backup power to your home in a fraction of a second. This means that your home will seamlessly switch to solar and battery power, and your appliances keep running without interruption. You may not even notice when an outage occurs.

The Lunar App will send you grid outage notifications and offer real-time insights into how your Lunar System is behaving during an outage, ensuring you stay informed and prepared.

Grid outage notifications

  • If you have notifications enabled in the Lunar App, you’ll be notified as soon as your Lunar System detects a grid outage, and you’ll be notified again once the grid is restored.

  • Ensure notifications are enabled by going to ‘Settings’ > ‘Your home overview’ > ‘Notification preferences.’ Please also make sure your device settings allow notifications from the Lunar App.

See how Lunar is powering your home in the Lunar App

In the Lunar App’s home screen, you’ll be able to see what’s happening in your home during an outage, for example:

  • Lunar’s prediction of how long your system could power your home at your current rate of electricity usage

  • Your battery’s state of charge

  • Your live home electricity usage and solar generation

If the circumstances allow, the Lunar System can keep you powered until the next morning, when the sun rises, powers your home, and recharges the battery all over again.

We recommend reducing the use of energy-intensive appliances —such as air conditioners, electric heaters, EV chargers, and dishwashers — if your battery's charge is getting low (20%), your power consumption is high, or if a power outage goes on for longer than a couple hours. The Lunar App can guide you through an outage, and as you turn off electrical loads, you can instantly see how much additional backup time your Lunar System can provide.

If your Lunar System's charge is very low (less than 10%) or your consumption is nearly at the maximum your system can provide, your home’s power system could "trip" (a safety mechanism that cuts power to prevent system overload). To avoid this, lower the usage of energy-intensive devices. This will help prevent a system trip and allow the Lunar System to continue supporting your home for as long as possible. If a brownout does occur, turn off any heavy load. The Lunar System will immediately attempt to restart and resume off-grid operation.

Can I add more backup loads after the Lunar System install?

The Lunar System should always be designed and installed properly to support your home consumption during an outage. However, if you add new heavy loads to your Lunar Bridge without approval from your installer, or your installer puts more loads into backup than your Lunar System can handle, you may be at risk of tripping the Lunar System and temporarily losing backup power to your home during an outage. To mitigate the risks of tripping the Lunar System, we recommend always consulting with your installer before adding more heavy loads to your home.

AC unit causing other loads to flicker or reset

When an air conditioner compressor starts, it draws a large surge of power for a few seconds. Depending on the load and the system's available output, this can affect other devices in the backup panel.

Use the symptom below to identify the cause:

Symptom

Likely cause

What to do

Lights briefly dim or flicker when AC starts, then stabilize

Normal AC startup surge — system is absorbing a brief power spike

No action needed. If it bothers the homeowner, a soft start (see below) will reduce the surge.

Sensitive electronics (Wi-Fi router, appliances, etc.) fully reset or power off when AC starts

High inrush current from AC compressor — the surge is large enough to momentarily destabilize other loads

Check the AC unit's LRA (Locked Rotor Amps — on the unit's data label). A soft start or Eaton smart breaker on the AC circuit will reduce inrush and prevent resets.

Flickering or resets happen while the AC is running (not just at startup)

Possible wiring issue or system operating near maximum output capacity

Check backup panel voltage (see below). Reduce other load usage and contact Lunar Installer Support if the issue continues.

Checking sub-panel voltage

If loads are resetting or the backup panel voltage seems abnormal, measure line-to-ground voltage at the backup sub-panel (L1-to-ground and L2-to-ground). Expected range is approximately 120V on each leg.

  • L1 and L2 both read ~120V, neutral-to-ground reads 0V → wiring is normal; the issue is inrush-related. Proceed with soft start or smart breaker.

  • Either leg reads significantly above ~124V (e.g. 130V+) → investigate for a loose neutral or wiring fault in the backup panel before commissioning or leaving the site.

  • Line-to-line voltage reads approximately 208V → the property may be on 120/208V three-phase service, which is not compatible with the Lunar System. See the AC Service Compatibility article.

Mitigating high AC inrush: soft start and smart breakers

Two solutions reduce AC compressor inrush and protect other backed-up loads:

  • Soft start device (e.g. SureStart or equivalent): installed on the AC unit, gradually ramps up the compressor motor to reduce startup surge. Recommended for any AC unit whose LRA is high relative to the system's available output.

  • Eaton AbleEdge smart breaker on the AC circuit: manages the load at the breaker level and can reduce the impact of inrush on the rest of the backed-up panel.

Note: A soft start or smart breaker is a site-level mitigation — it does not change the Lunar System configuration. Consult the homeowner before adding any device to the backup panel.

Did this answer your question?